Medium Voltage 240mm2 Copper XLPE Insulated PVC sheated Power Cable21/35kV CU/XLPE/PVC(or PE) Power Cable
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Chinese Type
2. Operating Characteristics
Rated voltage U0/U(Um): 21/35(40.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
4. Manufacturing Standards IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
 Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
1x50mm 2 | 9.3 | 0.12 | 2.0 | 35.1 | 0.387 |
1x70mm 2 | 9.3 | 0.12 | 2.1 | 37.0 | 0.268 |
1x95mm 2 | 9.3 | 0.12 | 2.1 | 38.6 | 0.193 |
1x120mm 2 | 9.3 | 0.12 | 2.2 | 40.2 | 0.153 |
1x150mm 2 | 9.3 | 0.12 | 2.2 | 41.8 | 0.124 |
1x185mm 2 | 9.3 | 0.12 | 2.3 | 43.6 | 0.0991 |
1x240mm 2 | 9.3 | 0.12 | 2.4 | 46.2 | 0.0754 |
1x300mm 2 | 9.3 | 0.12 | 2.4 | 48.2 | 0.0601 |
1x400mm 2 | 9.3 | 0.12 | 2.5 | 51.6 | 0.0470 |
1x500mm 2 | 9.3 | 0.12 | 2.6 | 55.5 | 0.0366 |
1x630mm 2 | 9.3 | 0.12 | 2.7 | 59.3 | 0.0283 |
1x800mm 2 | 9.3 | 0.12 | 2.9 | 63.5 | 0.0221 |
 Medium Voltage 240mm2 Copper XLPE Insulated PVC sheated Power Cable
21/35kV CU/XLPE/PVC(or PE) Power Cable
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Chinese Type
2. Operating Characteristics
Rated voltage U0/U(Um): 21/35(40.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
4. Manufacturing Standards IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
 Size |
Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 20ºC(Ω/km) |
1x50mm 2 | 9.3 | 0.12 | 2.0 | 35.1 | 0.387 |
1x70mm 2 | 9.3 | 0.12 | 2.1 | 37.0 | 0.268 |
1x95mm 2 | 9.3 | 0.12 | 2.1 | 38.6 | 0.193 |
1x120mm 2 | 9.3 | 0.12 | 2.2 | 40.2 | 0.153 |
1x150mm 2 | 9.3 | 0.12 | 2.2 | 41.8 | 0.124 |
1x185mm 2 | 9.3 | 0.12 | 2.3 | 43.6 | 0.0991 |
1x240mm 2 | 9.3 | 0.12 | 2.4 | 46.2 | 0.0754 |
1x300mm 2 | 9.3 | 0.12 | 2.4 | 48.2 | 0.0601 |
1x400mm 2 | 9.3 | 0.12 | 2.5 | 51.6 | 0.0470 |
1x500mm 2 | 9.3 | 0.12 | 2.6 | 55.5 | 0.0366 |
1x630mm 2 | 9.3 | 0.12 | 2.7 | 59.3 | 0.0283 |
1x800mm 2 | 9.3 | 0.12 | 2.9 | 63.5 | 0.0221 |
Â
The automobile cable is a kind of connecting wire inside the automobile, which is mainly used for current transmission of batteries, instruments, lamps, etc. Due to the particularity of the automobile industry, the manufacturing process of automobile cables is also more special than other ordinary wires. In most cases, it is required that the car cable will be cold and high temperature resistant.