Working principle and configuration of gas chromatograph for liquor composition analysis
Beijing Huasheng Spectrum Instrument Co., Ltd.
one,
Technical field
analysis
The technical field, in particular, relates to a liquor chromatography application package, and a liquor gas chromatography analysis system and a method for detecting liquor using the system. Chromatography is a physical and chemical analysis method that utilizes the difference in partition coefficients between two phases of a mixture of substances. When the solute moves relative to each other, the materials are distributed multiple times between the two phases, so that the components are obtained. Separation. Chromatography has many advantages. It has high separation efficiency, wide application range, fast analysis speed, low sample consumption and high sensitivity. Separation and measurement are completed at one time, easy to automate, and can be used in industrial processes.
1
3
More than 10,000 homes, corresponding to thousands of other liquor testing institutions. The determination of methanol, heavy metals (lead, manganese), miscitol, and food additives in liquor is a project that must be enforced in the national standards; ethanol concentration, total acid, total ester, solids and characteristic aroma The determination of the content of the ingredients is an item of product quality standard testing. In the production process control, through the analysis and detection of liquor quality indicators such as total acid, total ester, ethanol concentration and aroma component content, the quality can be judged initially, and it can be traced back to the control of production process and scientific research, such as Dregs fermentation, product design, wine processing, new product development, process innovation detection and control, etc. Therefore, the analysis and testing of liquor has an important role and significance in the monitoring and quality control of liquor production. The monitoring of liquor market and the identification of real wine and fake wine are also major concerns of the people.
2
"
Liquor special gas chromatographâ€
. Including qualitative methods, quantitative methods, precision test methods, technical points of actual analysis of liquor. Also includes sample injection method, column installation method, and auxiliaryinstrument
How to use the gas source and chromatography workstation. The improvement of the present invention compared to the prior art is:
1
2
3
4
5
6
7
3
B
Monophenylethyl alcohol (rice type),3
Monomethylthiopropanol (sesame type), an improved analytical program, including a complete set of two columns to complete the four specified components, and the corresponding experimental conditions, detailed qualitative, quantitative, reproducible analytical techniques. At the same time, there are two qualitative standards and corresponding chromatograms in the package, which can help the user to quickly complete the qualitative determination of all components of the liquor. The quantitative standard and the reference component correction factor table provided can quickly and easily complete the whole component quantification of liquor.Beijing Huasheng Spectrum Instrument Co., Ltd.
Produced exclusively for wineries
Liquor analysis gas chromatograph
Using a hydrogen flame ionization detector,
DNP
The column is packed to complete the analysis of more than ten components such as alcohol, aldehyde and ester in the liquor. It is also possible to use a capillary column to analyze forty components of alcohol, aldehyde, ester, acid, etc. in liquor. The results of the analysis are in full compliance with international standards.With white wine composition analysis chromatograph configuration:
SP-2100A
The instrument has a stylish appearance, beautiful appearance, humanized design, and convenient operation. Full microcomputer control, Chinese interface, large screen LCD display, stable performance. The instrument can be widely used in environmental protection, environmental monitoring, agricultural, petrochemical enterprises in the routine analysis of control and detection, can also be used for routine analysis of medicine, health and epidemic prevention and research institutions; can also be converted into dedicated chromatography according to different needs of users instrument.
SP-2100A
main feature
Simple operation: the instrument adopts large-screen liquid crystal display, full Chinese operation interface, convenient for user operation; screen switching is simple and clear, all electrical control parameter settings and faults of the instrument are displayed, allowing the operator to master in a short time How to use the instrument.
Self-diagnosis function: After starting the instrument, the instrument can diagnose each part of the electrical unit and display the diagnosis result in time.
Four independent temperature control systems: oven, injector box,
TCD
Both the detector box and the ionization detector box can independently control their temperature.Real-time zero adjustment: The output can be zeroed in real time before analysis.
Fifth-order temperature programming: heating rate
0.1~30°C/min
Optional.Injector: Three sets of fill injectors or two capillary injectors can be installed simultaneously.
Four detectors are available:
TCD
,FID
,ECD
,FPD
Simultaneous installation3
Kind of detector.TCD
Sensitivity
≥5000mV.ml/mg(n-C16)
FID
Detection limit
≤1×10-11g/S (n-C16)
ECD
Detection limit
≤4×10-13g/S (
Hexachlorobenzene)
FPD[P]
Detection limit
≤5×10-12g/S (
Methyl parathion)
[S]
Detection limit
≤1×10-10g/S (
Methyl parathion )
20 ° C
~400 ° C
Injection box: above room temperature
20 ° C
~400 ° C
Ionization box: above room temperature
20 ° C
~400°CTCD
Monitor box: above room temperature
20 ° C
~ 350 ° C
AC220V±22V
50Hz±0.5Hz
15A
Dimensions: high
×
width×
deep445×550×560mm3
Net weight: about
38Kg
Genuine Flip Cover Leather Case
Genuine Flip Cover Leather Case,Cover Leather Case,Flip Cover Leather Case,Genuine Leather Case
Guangzhou Jiaqi International Trade Co., Ltd , https://www.make-case.com