Drop Type Fuse RW10-10 F

Model NO.: RW10-10 F
Execution Standard: National Standard
Fusing Speed: High-Speed Circuit Breaker
Brand: Safee
Fusing Device: Open Frame
Factory: Yes
Function: Overcurrent Protection
Operation: Manual Type
Breaking Capacity: High
Usaga: High Voltage
Standard: IEC60282
OEM/ODM: Yes
Arc-Extinguishing Medium: Air
Trademark: SAFEE
Transport Package: Carton, Pallet, Bag
Specification: GB CE
Origin: Hebei China
Product Description:
Outdoor drop fuse is suitable for up to and including 35 kv voltage frequency 50 hz in the power system, transmission lines, power transformer overload and short circuit protection, only device.the rated load current, a mechanical life 2000 times or more
Drop type fuse and tensile load falling type fuse is outdoor high voltage protection appliances, it assembled in distribution transformer high voltage side or distribution lines trunk road, transmission lines, power transformer overload and short circuit protection and device.the rated load current. According to fuse protection, the large amount of open circuit current should be no less than the maximum short-circuit current of protected electrical circuit;Minimum melting current should be no greater than was the minimum short circuit current protection circuit.
When installing fuse, should tighten all of the parts, to prevent contact part overheating during normal operation.
For three-phase install fuse piece, even if an action, the other two shall be replaced, because the other two, though not damaged, but is close to a point, to the extent of the damage.Vacuum fuse
Fuse cannot be installed on the severe vibration, dust, pollution, moist places.
The fuse save and check the fuse installation and replacement
To fall or the vibration of the fuse should be tested before use (dc resistance, the parts are in good condition)
Place a long time of fuse factory/outbound should be check again when the resistance value.
Fuse should be stored in dry places.
In replacement of fuse piece, should be replaced in the action after 10 minutes. If after fusing a movement found smoke emission tube or noisy phenomenon, should not replace the fuse, need, fusing and isolation are allowed to change after a power source.
For in near the power supply device or a charged conductor, should meet the safety regulations
1.ISO9001,C
2.90%exportation
3.good quality and reasonable price

Product Description
Outdoor Fuse Cutout 10KV-36KV
Application: Protection device for protecting power system from over-load and short-circuit failure. 
Ratings: 10kV-36kV. 
Standards: IEC 600282-2

Features: 
1, High over-current protection capability, high breaking current. 
2, High industrial frequency withstands voltage, and mechanical strength, etc. 
3, High quality on strict testing. 

Technical Data: 
Rated voltage: 11kV to 66kV. 
Rated current: Up to 200A. 
main technical parameters

 

 

 

TYPE

 

Rated

Voltage

(KV)

 

Rated

Current

(A)

 

Breaking

Current

(A)

 

Impulse

Voltage

(BIL)

(KV)

 

Power-frequency wishtand voltage

(KV)

 

Leakage

Distance

(MM)

Voltage

 

Weight

(KG)

 

Dimensions

(CM)

RW3

10

100

6300

100

42

230

6.2

48X27X12

RW3

10

200

8000

100

42

230

6.5

48X27X12

HRW3

10

100

6300

100

42

230

6.2

 

HRW3

10

200

8000

110

42

230

6.2

 

RW7

10

100

6300

110

42

230

6.2

48X27X12

RW7

10

200

8000

110

42

230

6.5

48X27X12

HRW7

12

100

6300

110

42

230

6.2

 

HRW7

12

200

8000

110

42

230

6.2

 

RW10-10F

12

100

6300

110

42

260

7.5

53X32X12

RW10-10F

12

200

8000

110

42

260

7.5

43X32X12

HRW10

12

100

6300

110

42

260

7.5

 

HRW10

12

200

8000

110

42

260

7.5

 

RW12

15

100

10000

110

40

250

7.5

40X34.5X11

RW12

15

200

12000

110

40

250

7.5

40X34.5X11

RW12

24

100

8000

150

65

540

12

49X35X14

RW12

24

200

12000

150

65

540

12

49X35X14

RW12

30

100

6000

170

70

700

15

56X38X14.5

RW12

30

200

8000

170

70

700

15

56X38X14.5

RW12

33

100

10000

170

70

720

15.5

57X38X14.5

RW12

33

200

12000

170

70

720

15.5

57X37X14.5

RW12

11

100

6000

110

42

340

7.5

49X27X11.5

RW12

11

200

8000

110

42

340

7.5

49X27X11.5

RW11

36

100

6000

110

42

340

16

90X40X13

RW11

36

200

8000

170

70

870

16

90X40X13

RW5

33

100

8000

170

70

820

27.5

67X17X15

RW5

33

200

10000

170

70

820

27.5

68X17X15

HRW9

10

100

6300

110

42

 

 

 

HRW9

10

300

8000

110

42

 

 

 

HRW11

12

100

6300

100

42

 

 

 

HRW11

12

200

8000

110

42

 

 

 

HPRW11

12

100

6300

100

42

 

 

 

HPRW11

12

200

8000

110

42

 

 

 

HRW12

12

100

6300

100

42

 

 

 

HRW12

12

200

8000

110

42

Drop Type Fuse RW10-10 F

flicker free Led Driver,adpot the new MCU technology to make the Triac Dimmable LED Driver better,flicker free,noise free,load free,match 99% dimmer,Private mould non-waterproof IP20 plastic housing series, Square and round types,CE/ROHS/SAA/ETL/TUV/EMC,Input voltage can be both 110V and 220V,Wattage can be 1-80W, Perfect dimming curve, constant current 350mA 700mA 900mA 1200mA,constant voltage 12V 24V 36V, parameters can be customization,OEM/ODM is supported,Same appearances but different sizes, forming a perfect product line,Use for led panel light,led strip light and other indoor led lights

Plastic Flicker Free Led Driver

Flicker Free Triac Dimmable LED Driver,Cob Downlight Flicker Free LED Driver,1200Ma Flicker Free Driver

HAURUI LIGHTING CO.,LTD , http://www.huaruileddriver.com

Posted on